2

The parameters related with ultrasound-guided MWA

ParameterAllALBI grade 1ALBI grade 2P
Patients, n 1839588
Antenna number2221.000b
Ablation points†2.4 (2–7)2.2 (1–5)2.5 (1–7)0.612a
Ablation time (s)*558.3±23.1 (478–600)592.5±21.1 (500–600)537.1±11.3 (478–600)0.328a
Ablation power (W)†55 (45–60)55 (45–60)50 (45–60)0.772a
Hydrodissection technology0.256b
Yes55 (30.1)25 (26.3)30 (34.1)
No128 (69.9)70 (73.7)58 (65.9)
CEUS guidance0.530b
Yes32 (17.5)15 (15.8)17 (19.3)
No151 (82.5)80 (84.2)71 (80.7)
3D visualization preoperative plan0.757b
Yes48 (26.2)24 (25.3)24 (27.3)
No135 (73.8)71 (74.7)64 (72.7)
Sessions0.031b
1165 (90.2)90 (94.7)75 (85.2)
> 118 (9.8)5 (5.3)13 (14.8)

Unless otherwise indicated data are number of patients, with percentage in parentheses. a Student t test; b Pearson χ2-test; * Data are means SD ± mean; † Data are medians, with data range. MWA, microwave ablation ALBI, albumin- bilirubin.